Catalogue | Environmental-, soil-, water-, food analysis | Sample analysis | BOD | BOD measurement system OxiTop®-i IS 6 / 12 |
InformationDetailsAlternatives/Accessories
BOD measurement system OxiTop®-i IS 6 / 12
Easy-to-use, respirometric measuring system for determining the biological oxygen demand (BOD). The method is based on changes of pressure in a closed system using measuring heads attached to the sample bottles. The BOD can be determined simultaneously in up to 6 or 12 samples.
Scope of supply: OxiTop®-i IS 6: 6 x measuring heads (3 x blue, 3 x grey), 6 x sample bottles PF600, 6 x rubber quivers, CO2 absorber, nitrification inhibitor, overflow measurement flasks, 6 x stirring rods, stirring rod remover, stirring platform SI 6
OxiTop®-i IS 12: 12 x measuring heads (6 x blue, 6 x grey), 12 x sample bottles PF600, 12 x rubber quivers, CO2 absorber, nitrification inhibitor, overflow measurement flasks, 12 x stirring rods, stirring rod remover, stirring platform SI 12
An incubator is required to operate the OxiTop®-i IS. Please order separately.
- No dilution of the sample required
- Direct reading of the BOD, the time course and the intermediate values on the graphical display of the measuring heads
- Input of the used sample volume directly at the measuring head
- Monitoring time between 1 and 7 days
- Permanent display of the current status at each measuring head
- Coloured measuring heads with adjustable, numerical sample identification
Scope of supply: OxiTop®-i IS 6: 6 x measuring heads (3 x blue, 3 x grey), 6 x sample bottles PF600, 6 x rubber quivers, CO2 absorber, nitrification inhibitor, overflow measurement flasks, 6 x stirring rods, stirring rod remover, stirring platform SI 6
OxiTop®-i IS 12: 12 x measuring heads (6 x blue, 6 x grey), 12 x sample bottles PF600, 12 x rubber quivers, CO2 absorber, nitrification inhibitor, overflow measurement flasks, 12 x stirring rods, stirring rod remover, stirring platform SI 12
An incubator is required to operate the OxiTop®-i IS. Please order separately.
Specifications | |
Pressure range: | 500 ... 1250 hPa |
BOD range: | 0 ... 4000 mg/l |
Display: | Graphical LCD, background-illuminated |
Power supply of measuring heads: Power supply of stirring platform: | 1 x CR 2450 100 ... 240 V, 50/60 Hz |
7.940 936 |
Data
Bestell Nr.
GHS
Signalwort
H-Satz
P-Satz
UN/Nr.
SDB
Bestell Nr.
7.940 936
GHS
Signalwort
Danger
H-Satz
H290 | H314
P-Satz
P280 | P301+P330+P331 | P305+P351+P338
UN/Nr.
1823
Bestell Nr.
4.667 879
GHS
Signalwort
Danger
H-Satz
H290 | H314
P-Satz
P280 | P301+P330+P331 | P305+P351+P338
UN/Nr.
Type | PK | ||
---|---|---|---|
OxiTop®-i IS 6Prod.No.7.940 936 | 1 | ||
OxiTop®-i IS 12Prod.No.4.667 879 | 1 |
Measuring heads OxiTop®-i | Xylem Analytics Germany (WTW) | |
Stirring platforms OxiTop® for BOD measurement | Xylem Analytics Germany (WTW) |
BOD measuring system OxiTop®-IDS for determination of aerobic degradation | Xylem Analytics Germany (WTW) | |
BOD Measuring system OxiTop®-IDS for determination of soil respiration | Xylem Analytics Germany (WTW) | |
BOD Measuring system OxiTop®-IDS for determination of biogas/microbiology | Xylem Analytics Germany (WTW) |