Tintometer 

Photometer MD50

Single-parameter photometer for analysing various parameters in water treatment. The device contains pre-programmed methods for different types of reagents. With the One-Time-Zero function, the device only needs to be zeroed once per sample. Data can be easily transferred to the AquaLX® app via NFC or to the PC software using a USB cable.

  • Robust, ergonomic design with rubber-protected sides for a firm grip
  • Display with coloured backlight shows the status of results and errors
  • Language-free user interface with icons and animations
  • Accurate and reproducible results
  • One-point calibration
  • Programming option for one customised method
  • NFC data transmission
  • USB-C connection
  • Automatic storage of the last 100 readings and protocols with time and date stamp
  • GLP compliant data backup
Scope of supply: Photometer, 3 x 24 mm round glass cuvettes with lid and sealing ring, screwdriver, 3 x stirring rods, 10 ml syringe, cleaning brush, USB-C to USB-A cable, carrying case, 2 x AA batteries, operating instructions, reagents (depending on variant)
Photometric measuring range:0 ... 3 Abs
Photometric accuracy:±3 % FS
Illuminants:LED
Dimensions (WxDxH):76 x 155 x 45 mm
Battery/rechargeable battery:2 x AA
IP code:IP 67
Photometer MD50


Photometer MD50
X

Item added to basket.

Photometer MD50

Customers also bought:

TypeMeasured rangePKCat. No.   
MD500.02 ... 6 mg/l Cl2 (Chlorine, tablet reagents)14700095  
MD500.02 ... 4 mg/l Cl2 (Chlorine, liquid reagents)14700096  
MD500.1 ... 10 mg/l CI2 HR (Chlorine, powder reagents)
0.02 ... 2 mg/l CI2 PP (Chlorine, powder reagents)
14700097  
MD500.02 ... 11 mg/l ClO2 (Chlorine dioxide, tablet reagents)14700098  
MD500.04 ... 3.8 mg/l ClO2 (Chlorine dioxide, powder reagents)14700099  
MD500.02 ... 2 mg/l O3 (Ozone, tablet reagents)14700100  
MD500.015 ... 1.2 mg/l O3 (Ozone, powder reagents)14700101  
MD505 ... 200 mg/l CI2 (Chlorine HR, tablet reagents)
0.2 ... 16 % NaOCI (Hypochlorite, tablet reagents)
14700102  
MD500.02 ... 4.5 mg/l Cl2 (Monochloramine, powder reagents and liquid reagents)14700103  
MD500.1 ... 2.5 mg/l CH4N2O (Urea, liquid reagents)
0.2 ... 5 mg/l CH4N2O (Urea, liquid reagents)
14700104  
MD500.03 ... 3 mg/l Mo (Molybdenum, powder reagents and liquid reagents)14700107  
MD500.6 ... 30 mg/l Mo (Molybdenum, tablet reagents)14700108  
MD500.3 ... 40 mg/l Mo (Molybdenum, powder reagents)14700109  
MD500.05 ... 5 mg/l Cu (Copper, tablet reagents)14700110  
MD500.05 ... 5 mg/l Cu (Copper, powder reagents)14700111  
MD500.05 ... 4 mg/L PO4 (Phosphate, tablet reagents)14700112  
MD500.06 ... 2.5 mg/L PO4 (Phosphate, powder reagents)14700113  
Accessories:
Cuvettes for photometers / Tintometer
Accessories for Lovibond® photometers / Tintometer
 USB-C cable / Tintometer
 Cuvette stand, acrylic glass / Tintometer